U-Match Series DC Inverter Service Manual
34
(4) Compensate 3℃ (LCD displays 03)
(5) Compensate 4℃ (LCD displays 04)
(6) Compensate 5℃ (LCD displays 05)
(7) Compensate 6℃ (LCD displays 06)
(8) Compensate 7℃ (LCD displays 07)
(9) Compensate 8℃ (LCD displays 08)
(10) Compensate 9℃ (LCD displays 09)
(11) Compensate 10℃ (LCD displays 10)
(12) Compensate 11℃ (LCD displays 11)
(13) Compensate 12℃ (LCD displays 12)
(14) Compensate 13℃ (LCD displays 13)
(15) Compensate 14℃ (LCD displays 14)
(16) Compensate 15℃ (LCD displays 15)
Note:
Indoor ambient temperature compensation can be set through wired controller (E.g. If 02 is
selected; it indicates the compensation temperature is 2℃. If the indoor ambient temperature detected
by the temperature sensor at air return is 29℃, the ambient temperature after compensation is
29℃-2℃=27℃).
After finishing setting, press Enter/Cancel button to save and exit setting. After entering this
interface, the system will exit this menu if there is no operation on the button within 20s. Normal off state
interface will be displayed and present setting will not be saved.
5 INSTALLATION OF WIRED CONTROLLER
5.1 Standard Accessories
Table 2-5-1 Standard Accessories of Wired Controller