Manual switch function (under indoor unit front panel)
Auto function
When setting the switch to "AUTO", it will run in AUTO mode. If receiving the signal, it will run according to the remote signal.
Test function
When setting the switch to "TEST", the unit will run in COOL mode, indoor fan will run at high speed, louver will run in SWING mode.
If receiving remote signal, the unit will run according to remote signal. If the sensor is open-circuited or short-circuited, buzzer will alarm.
Run function
When setting the switch to "RUN", the unit will run according to remote signal.
Stop function
When setting the switch to "STOP", the unit will stop running.
Sleep function
In COOL or DRY mode, when the set sleeping has run for 1 hour, Tset will rise 1℃; 2 hours later,Tset will rise 2℃. Indoor fan will run at low speed
In HEAT mode, when the set sleeping has run for 1 hour, Tset will fall 1℃;
2 hours later, Tset will fall 2℃Indoor fan will run at low speed
Auto FAN
In this mode, according to ambient temperature,indoor fan will select High, Middle, Low fan speed.
Timing Function
Time on
The unit will restart in the old mode with memory function after power is turned off.
Memory Function
Time off
The unit is stopped when the timer for turning on acts. When it is time to turn on, the PCB will act in the set mode.
The distance of setting twice is 0.5hour and time range is 0.5-24hours.
Set the timer for turning off function when the unit is turned on, when it is time to turn off, the unit will be switched
off. The distance of setting twice is 0.5 hour and time range is 0.5-24hours.
22