7
Technical Information
Service Manual
2.4 Cooling and Heating Data Sheet in Rated Frequency
Rated cooling
condition(°F) (DB/WB)
Model
Pressure of gas pipe
connecting indoor
and outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(Hz)
Indoor Outdoor PSIG T1 (°F) T2 (°F)
81/66 95/75 09/12K 123.2~145
in:46~52
out:52~57
in:122~176
out:99~109
Suprt High High 58
Rated heating
condition(°F) (DB/WB)
Model
Pressure of gas pipe
connecting indoor
and outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(Hz)
Indoor Outdoor P (MPa) T1 (°F) T2 (°F)
68/- 45/43 09/12K 362.3~435
in:122~176
out:99~109
in:34~37
out:36~41
Super High High 56
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 24.6ft.
Cooling:
Heating:
2.5 Noise Curve
18K
18K
46
48
50
52
54
56
58
60
20 30 40 50 60 70 80 90 100
Compressor frequency(Hz)
Noise dB(A)
Heating
Cooling
45
50
35
40
30
20
25
Indoor fan motor rotating speed
Super
High
Super
Low
Middle
High
Middle
Low
High Middle Low
Noise dB(A)
18K
45
50
35
40
30
20
15
25
Indoor side noise Outdoor side noise
Indoor fan motor rotating speed
Super
High
Super
Low
Middle
High
Middle
Low
High Middle Low
40
42
44
46
48
50
52
54
20 030450607080
Compressor frequency(Hz)
Noise dB(A)
Noise dB(A)
Heating
Cooling
09K
12K