Troubleshooting List for the Operator
The Groen kettle is designed to operate smoothly and efficiently if properly maintained. However, the following
is a list of checks to make in the event of a problem. If the actions suggested in this list do not solve the
problem, call your Groen Certified Service Agency. To get the phone number of the nearest agency, call the
your Area Groen representative or the Groen Parts and Service Department.
A. All Models
SYMPTOM WHAT TO CHECK
a. That the main gas cock is completely open (handle
is in line with the gas pipe).
b. That the toggle switch is ON.
c. That the thermostat dial is at the correct setting.
d. Lighting procedure. See the "Operation" Section of
this manual.
e. Jacket water level. If it is low, see "Jacket Filling" in
the "Preventive Maintenance" section of this
manual.
f. That electric power is turned on at the circuit
breaker or fuse box, and that power is being
supplied to your building.
Pilot burner and/or burner will not light or goes
out after working for a while.
g. Gas supply to your building.
Kettle continues heating after it reaches the
desired temperature.
a. That the thermostat dial is at the correct setting.
a.
That th
e thermostat dial is at the correct setting.
b. That the ON/OFF switch is ON.
Kettle stops heating before it reaches the
desired temperature.
c. Reading of the pressure/vacuum gauge. If it is not
20 to 30 below zero when the kettle is cold, see
"Jacket Vacuum" in the "Preventive Maintenance"
section of this manual.
Kettle heats slowly. a. Reading of the pressure/vacuum gauge. If it is not
20 to 30 below zero when the kettle is cold, see
"Jacket Vacuum" in the "Preventive Maintenance"
section of this manual.
Safety valve pops. a. Reading of the pressure/vacuum gauge. If it is not
20 to 30 below zero when the kettle is cold, see
"Jacket Vacuum" in the "Preventive Maintenance"
section of this manual.
B. Models with Standing Pilot Ignition
SYMPTOM WHAT TO CHECK
Pilot burner will not light. a. Lighting procedure. See the "Operation" section of
this manual.
Pilot flame goes out when reset button is released. a. Lighting procedure. See the "Operation" section of
this manual.
12