Section 1 - Installation
The Groen Kettle is provided with complete internal
wiring and is ready for immediate connection. Wiring
diagrams are provided in this manual and on the
inside of the control housing service panel. Any
mechanical or electrical changes must be approved
by Groen’s Food Service Engineering Department.
WARNING
INSTALLATION OF THE KETTLE MUST BE
DONE BY PERSONNEL QUALIFIED TO WORK
WITH ELECTRICITY. IMPROPER INSTALLATION
CAN RESULT IN INJURY TO PERSONNEL
AND/OR DAMAGE TO EQUIPMENT.
The completed unit has been operated at the factory
to test all controls and heater elements.
1.1 Placement
Set the kettle in place and level it by turning the
bullet feet to adjust leg length. Allow clearance
around the unit for cleaning, maintenance and
service.
1.2 Initial Checks
1.2.1 Confirm that the jacket water level is
above the mid point of sight glass. If the
level is low, follow the instructions under
“Jacket Filling and Water Treatment,”
Page 13.
1.2.2 The open end of
the elbow on the
outlet of the safety
valve must face
downward. If it
does not, turn it to
the correct
position.
1.3 Providing Power
1.3.1 Provide electrical power specified on the
equipment electrical information plate.
Observe all local and national codes, and
all regulations in force at the time of
installation.
1.3.2 Bringing the electrical service through the
entrance at the rear of the support
housing with one inch conduit, making a
watertight connection with the incoming
lines. Observe all local and national
codes, and all regulations in force at the
time of installation.
DANGER
ELECTRICALLY EARTH THE UNIT AT THE
TERMINAL PROVIDED. FAILURE TO EARTH
UNIT COULD RESULT IN ELECTROCUTION AND
DEATH.
1.3.3 Electrically earth the unit at the terminal
provided.
Check the following to confirm that your DEE/4
kettle is properly installed:
• Room for cleaning and servicing
• The kettle is level
• The correct amount of water is in the kettle
jacket
• Safety valve is pointed down
• Unit is connected with a waterproof supply of
the proper voltage, phase and amperage
rating
ELECTRICAL SUPPLY CONNECTION REQUIREMENTS
Unit DEE/20 DEE/40 DEE/60
230 Volt - 1 Phase 57 Amperes 96 Amperes 96 Amperes
400 Volt - 3 Phase 57 Amperes 96 Amperes 96 Amperes