Power on/off Battery
20
6.2 Power on Battery
Power on single battery by pressing POWER button
Close the breaker that is connected
with positive and negative power
cables.
Press POWER button for two seconds
and observe the LED indication on
panel.
1. If both RUN and SOC lights turn on
normal, battery powers on successfully;
2. If ALM light turns red, there is a failure
and should be fixed before powering on
again.
Power on single battery by PCS activation
Close the breaker that is connected
with positive and negative power
cables.
PV or mains supply powers PCS.
1.PCS in ON position;
2, PCS HMI screen indicates normal PV or
mains supply input.
PCS voltage signal activates battery.
1. If RUN light and SOC lights on battery
indicate normal, battery powers on
successfully;
2. If the ALM light turns red, the indication
shows a failure. The failure shall be fixed
before powering on again.
Power on parallel-connected batteries by pressing POWER button
Close the breaker that is connected
with positive and negative power
cables.
Press POWER button for two
seconds within 30 seconds and
observe the LED indication on two
panels.
1. If RUN and SOC lights on both batteries
turn on normal, and the RUN lights on both
batteries flicker for five times, two batteries
power on successfully and communication
between batteries works;
2. If ALM light of one or both batteries turn
red, there is a parallel failure and should be
fixed before powering on again.
Power on parallel-connected batteries by PCS activation
Close the breaker that is connected
with positive and negative power
cables.
PV or mains supply powers PCS.
1. PCS in ON position;
2. PCS HMI screen indicates normal PV or