Specification
8
Domestic air conditioner
4.1*21*1 hctif*egats*woR regnahcxe
TECHNICAL SPECIFICATIONS-OTHERS
Refrigerant
circuit
Refrigerant type R32
Refrigerant charge KG
0.55
Maximum allowable distance
between indoor an outdoor
M
20
Maximum allowable level difference
●
m 10
Refrigerant control CAPILLARY
Piping connections
(external diameter)
liquid mm Φ6.35
gas mm Φ9.52
drain
●
mm Φ16
Heat insulation type Both liquid and Gas pipes
●
Max. piping Length m
●
20
Max. Level Difference m 10
Chargeless m 5
Amount of Additional Charge of Refrigerant g/m 20
Note: the data are based on the conditions shown in the table below
htgnel gnipiP gnitaeh gnilooc
Indoor: 27 DB/19 WB℃ ℃
Outdoor: 35 DB/24 WB℃ ℃
Indoor:20 DB℃
Outdoor: 7 DB/6 WB℃ ℃
5m
3.Sensors list
type Description Qty
Ambient sensor Its used for detecting temperature of outdoor side
1
Defrosting sensor Its used for controlling outdoor defrosting at heating mode
Discharging sensor Its used for compressor in case of over-heat
Conversation formulae
Kcal/h= kW×860
Btu/h= kW×3414
cfm=m³/min×35.3