Functions and control
14
Domestic air conditioner
7.Outdoor Functions and Control
7.1 Main functions and control specification
7
.1.1 The operation frequency of outdoor unit and its control
7.1.1.1 The operation frequency control of compressor
The operation frequency scope of compressor
Mode Minimu
m operation frequency Maximum operation frequency
75Hz
27Hz cooling
99Hz
27Hz heating
7.1.1.2 The starting of compressor
When the compressor is started for the first time, it must be kept under the conditions of
38Hz,58Hz,88Hz for 30second,one minute, one minute (the overheating protection of the outdoor unit
air-blowing temperature, immediately decrease the frequency when the compressor is overflowing and
releasing the pressure)then it can be operated towards the target frequency. When the machine runs
normally, there’s no such process. After starting the compressor for operation, the compressor should
run according to the calculated frequency, and every determined frequency for protection should be
prior to the calculated frequency.
7.1.1.3 The speeds of increasing or decreasing the frequency of the compressor
The speed of increasing or decreasing the frequency rapidly 1 -----------1HZ/second
The speed of increasing or decreasing the frequency slowly 2 -----------1HZ/10seconds
7.1.1.4 The calculation of the compressors frequency
Refrigeration/dehumidification mode:
outdoor environment control Pn=(Nh_c- S_c)*1050
Pn=(Nh_c- S_c) *1050 PID control
Heating mode:
Pn=(S_c -Nh_c) *1060
Pn=(S_c -Nh_c) *1060
outdoor environment control
PID control
(Nh_c=indoor
environment temperature S_c=setting temperature)
1The minimum/maximum frequency limitation
AWhile refrigerating: F-MAX-r is the maximum operation frequency of the compressor; F-MIN-r is the
minimum operation frequency of the compressor.
BWhile heating: F-MAX-d is the maximum operation frequency of the compressor; F-MIN-d is the
minimum operation frequency of the compressor.
2The frequency limitation which is affected by the environment temperature.
(Wh_c= environment temperature)
Heating mode:
Serial No. Temperature scope
Frequency limitation
1 Wh_c<-12 Max_hz1 99 HZ

Other manuals for Haier 1U25YEEFRA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier 1U25YEEFRA and is the answer not in the manual?

Haier 1U25YEEFRA Specifications

General IconGeneral
BrandHaier
Model1U25YEEFRA
CategoryAir Conditioner
LanguageEnglish

Related product manuals