Functions and control
15
Domestic air conditioner
2 Wh_c<-8 Max_hz2 99 HZ
3 Wh_c<-2 Max_hz3 99
HZ
4 Wh_c<5 Max_hz4 99
HZ
5 Wh_c<10 Max_hz5 80
HZ
6 Wh_c<17 Max_hz6
67 HZ
7 Wh_c<20 Max_hz7
63
HZ
8
Wh_c>=20
Max_hz8
5
52 HZ
Remarks: The above are the maximum frequency limitations of the complete appliance which are
affected by the environment, and they have nothing to do with the ability of the indoor unit.
Refrigeration/dehumidification mode:
Serial No. Temperature scope
Frequency limitation
1 Wh_c<16 Max_hz1 44 HZ
2 Wh_c<22 Max_hz2 51 HZ
3 Wh_c<29 Max_hz3 55 HZ
4 Wh_c<32 Max_hz4 65 HZ
5 Wh_c<40 Max_hz5 69 HZ
6 Wh_c<48 Max_hz6 56 HZ
7 Wh_c>=48 Max_hz7 46 HZ
Remarks: the above are not only the maximum frequency limitations of the complete appliance
which are affected by the environment, but also the maximum ability limitation of the system. When the
starting ability is not the maximum, its maximum frequency limitation is calculated by the following
●
equations:
The frequency limitation which is affected by the temperature and under the condition of actual
ability=the actual running system ability*the maximum frequency which is limited by the temperature
and under the condition of maximum ability/the maximum designing ability of the system
Refrigeration/dehumidification mode:
●
Heating mode:
F
●
-
The calculation of the actual output frequency:
●
F= F-ED-*(rated frequency)×K
ED-*(rated frequency)= The frequency which is limited by the outdoor environment temperature
Notes:
The indoor setting
airflow speed
Low Medium Quiet
The percentage of the
rated frequency K 70% 85%
The
indoor setting
airflow speed
Low Medium Quiet
The percentage of the
rated frequency K
90%
50%
80% 51%