2U14CS1ERA-SM
Service diagnosis

Domestic Air Conditioner
7.4.1
Thermistor or Related Abnormality
Indoor Display E1: Room temperature sensor failure
E2: Heat-exchange sensor failure
outdoor display LED1 flash 10 times˖Frost-removing temperature sensor failure
LED1 flash 11 times˖Suction temperature sensor failure
LED1 flash 12 times˖Ambient temperature sensor failure
LED1 flash 13 times˖Exhaust temperature sensor failure
Method of The temperatures detected by the thermistors are used to determine thermistor errors
Malfunction
Detection
Malfunction when the thermistor input is more than 4.92V or less than 0.08V during compressor
Decision operation.
Conditions
z Note: The values vary slightly in some models
Supposed Ŷ Faulty connector connection
Causes Ŷ Faulty thermistor
Ŷ Faulty PCB
Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or else parts
damage may be occurred.
Thermistor resistance check method:
Remove the connector of the thermistor on the PCB, and measure the resistance of thermistor using tester.The relationship
between normal temperature and resistance is shown in the value of indoor thermistor.
Thermistor resistance check
Is it normal?
Yes
NO
Yes
Is it normal?
NO
Check the connector onnection.
Replace the thermistor
Replace the indoor unit PCB
Correct the connection

Other manuals for Haier 2U14CS1ERA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier 2U14CS1ERA and is the answer not in the manual?

Haier 2U14CS1ERA Specifications

General IconGeneral
BrandHaier
Model2U14CS1ERA
CategoryAir Conditioner
LanguageEnglish

Related product manuals