Service diagnosis
58
Domestic Air Conditioner
7.4.5 IPM protection
Outdoor display
LED1 flash 2 times
Method of
IPM protection is detected by checking the compressor running condition and so on
Malfunction
Detection
Malfunction
Ƶ
The system leads to IPM protection due to over current
Decision
Ƶ
The compressor faulty leads to IPM protection
Conditions
Ƶ
circuit component of IPM is broken and led to IPM protection
Supposed
Ƶ
IPM protection dues to the compressor faulty
Causes
Ƶ
IPM protection dues to faulty PCB of IPM module
Ƶ
Compressor wiring disconnected
Troubleshooting
* Caution
Be sure to turn off power switch before connect or disconnect connector, or
else parts damage may be occurred.
Electrify the machine again and turn it on
with the remote controller,If malfunctions
are reported before or upon the
compressor being started up,
IPM Module is damaged and
needs replacing.
1The system may have been over or under charged with gas, which can be judged through the pressure of the
measuring system.
2The shaft of compressor is seized and the compressor needs replacing.
<(6
12
The compressor is started normally, but
malfunctions are reported after it has run for
some time.
Malfunction unsolved

Other manuals for Haier 2U14CS1ERA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier 2U14CS1ERA and is the answer not in the manual?

Haier 2U14CS1ERA Specifications

General IconGeneral
BrandHaier
Model2U14CS1ERA
CategoryAir Conditioner
LanguageEnglish

Related product manuals