5. Remove Wiring Cover from inside the hood. Set cover and mounting screws
aside.
6. Remove the appropriate electrical knockout by inserting a screwdriver. Then
snip or break the attachment points.
English
6
4. Remove Damper/Duct Connector from inside the hood. Set connector aside
with mounting screws and parts bag.
7. Remove either top or back wiring knockout and install approved electrical
conduit according to national electrical code.
Damper/Duct
Connector
Conduit