Operation
Sleep Operation
If the fan speed is high or medium before
setting for the sleep, set for low speed
after sleeping.
Note to the power failure resume:
press the sleep button ten times in five seconds
and enter this function after hearing four sounds.
And press the sleep button ten times within five
seconds and leave this function after hearing two
sounds.
NOTE:
With the power failure resume, when setting the
TIMER ON, TIMER OFF and TIMER ON/OFF,
it’s memorized as shutdown status when resuming
after power out
.
5. Set the fan speed change when sleeping
Before going to bed, you can simply press the
SLEEP
button and unit will operate in SLEEP
mode and b
ring you a sound sleep.
Use of SLEE
P function
After the unit sta
rts, set the operation status,
then press SLEEP
button before which the
clo
ck must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts, temp. will
beco
me about 2
O
F higher than temp.setting.
A
fter
another 1 hour
s, temp. rises
about 2
The unit will
run for further 6 hours then stops
Temp. is higher than temp. setting so that room
tempe
rature won't be too Iow for your sleep.
SLEEP operation starts SLEEP operation stops
SLEEP
ope
ration starts
SLEEP
ope
ration stops
Approx.6hrs
1 hr
1 hr
1 hr
3 hrs
3 hrs
Rises about 2
O
F
Rises about 2
O
F
Temp.setting
Temp.setting
Unit stop
Unit stop
In COOL, DRY mode
In HE
AT mode
Decreases about 4
O
F
1 hr
2.
3.
In HE
AT mode
1 hours after SLEEP mode sta
rts, temp
will become about 4
O
F lower than temp.
setting
. After another 1 hours, temp
decrease about 4
O
F further. After more
another 3 hour
s, temp. rises about 2
O
F
fu
rther. The unit will run for further 3
hours then stop
s. Temp. is lower than
tem
p. setting so that room temperature
won't be too high for your sleep.
In
AUTO mode
The unit ope
rates in corresponding sleep
mode adapted to the automatically selected
ope
ration mode.
4. In FAN mode
It has no SLEEP function.
POWER/SOFT Operation
(1)
POWER Operation
(2)
SOFT Operation
4
When you need rapid heating or cooling, you can use this function.
In COOL mode, fan speed automatically takes high speed of
AUTO fan mode. In HEAT mode, fan speed automatically takes
medium speed of AUTO fan mode.
You can use this function when silence is needed for rest or reading.
In SOFT operation mode, fan speed
automatically takes low speed
of AUTO fan mode.
Note˖
During POWER operation, in rapid HEAT or COOL modethe room
will show uniform temperature distribution. Long period
SOFT operation will cause effect of not too cool or not too warm.
To cancel POWER or SOFT operation
Press POWER/SOFT button again, POWER or SOFT
disappears.
6.
HEALTHY Operation
Healthy Negative ions
The anion generator in the airconditioner can
generate a lot of anion effectively balance the
quantity of position and anion in the air and also
to kill bacteria and speed up the dust sediment in
the room and finally clean the air in the room.
O
F further.
Rises about 2
O
F
Decreases about 4
O
F

Other manuals for Haier HSU18VHJ(DB)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier HSU18VHJ(DB) and is the answer not in the manual?

Haier HSU18VHJ(DB) Specifications

General IconGeneral
BrandHaier
ModelHSU18VHJ(DB)
CategoryInverter
LanguageEnglish

Related product manuals