8 - Technical specifications
104
Pump Model 463/12.0
Filters and Nozzles
Possible options:
*depending on selected nozzles
**not with PrimeFlow system
Temperature and Pressure Ranges
Filter name
Mesh Gauze width Color EasyClean Cyclone In-line** Tank strainer Nozzle
18 1.00 mm White - - - Yes -
300.60 mmGreenYes----
50 0.30 mm Blue Yes, standard - Yes* - Yes*
80 0.18 mm Red Yes Yes, standard Yes* - Yes*
100 0.15 mm Yellow - - Yes* - Yes*
Spray liquid system
Operating temperature range 2 - 40 °C
Operating pressure for the safety valve 15 bar
Max. pressure on the pressure manifold 20 bar
Max. pressure on the suction manifold 1.5 bar
Hydraulic system
Max. operating temperature 75 °C
Operating pressure from the tractor 190 - 210 bar