Automatic electrical shutdown system
(additional equipment)
This is characterized by a brief flashing of all
pilot lamps once the starter key has been turned
to position I (Fig. 14).
Important !
If the engine cuts out immediately after starting
or switches off by itself during operation, a
monitoring element in the automatic shutdown
system has tripped. The corresponding indicator
light (Fig. 14, positions 2 - 4) will come on.
After the engine has stopped, the display contin-
ues to glow for about 2 minutes.
The electrical device then switches itself off au-
tomatically.
The display lights up again after the start key
has been turned back to position 0 and then to
position I again.
Trace and eliminate the cause of the operating
fault before trying to restart the engine
(see chapter 6.2.).
The display light goes out when the engine is
next started.
Even with automatic shutdown monitoring
the oil level must be checked every 8 – 15
operating hours (Chapter 5.2.1.).
4.3. Stopping the engine
16
– Move the speed adjustment lever „1“ back
to the STOP position. The engine cuts out.
Note:
Engines with a fixed lower idling speed cannot
be switched off using the speed adjustment
lever. See the paragraph entitled „Other ways of
switching off the engine“.
Other ways of switching off the engine
1. Fuel shut-off valve, stop solenoid
(optional extra)
– Turn ignition key to the 0 position. The engine
cuts out, Fig. 18.