2L41C, 2M41, 2M41Z Faults
HATZ
93Operator’s Manual
Safety notes
CAUTION
Danger when switching off the engine from the emergency
operation mode.
During the emergency operation mode, the engine can only be
switched off with the starting key if the emergency start lever is
first returned to its home position.
CAUTION
Danger of later engine damage.
The monitoring components (oil pressure, charge control and
engine temperature) are deactivated in emergency operation.
The oil level must be checked before the emergency opera-
tion phase.
NOTICE
i
If the emergency operation mode is used, the risk transfers to
the operator (the Motorenfabrik HATZ does not accept liabil-
ity in this case).
Immediately after the emergency operation phase, deter-
mine the cause of the fault.
Have the Hatz service station supply the emergency start
lever with a new lead seal.
Overview
Pos. Designation
2 Emergency start lever

Table of Contents