How To: Clean the TurboCell
13
Cell cleaning frequency is dependent on several factors; pH & calcium levels have the
greatest effect on how often cells requires cleaning. In pH environments between (7.2 -
7.8) cells typically require cleaning 3-4 times a year (with moderate calcium levels).
Holding the cell up to a light source, inspect for calcium
deposits. Even if a TurboCell appears clean, it may still
require cleaning if salt accuracy is off AND/OR chlorine
production has diminished.
Wear Protective Equipment
If the cell requires cleaning, please wear protective
equipment. It is highly recommended to use a
Hayward Cell Cleaning Stand as shown on the right
(GLX-CELLSTAND)
Turn Pump Off & Remove Cell
Step 1
Clean Cell Calcified Cell
Step 2
NOTE: ALWAYS WEAR PROPER EYE PROTECTION AND PROTECTIVE GLOVES.
MIX SOLUTION AND CLEAN CELL ONLY IN A WELL VENTILATED AREA.
MURIATIC AND OTHER ACIDS CAN CAUSE SEVERE INJURY, BURNS AND RESPIRATORY PROBLEMS IF
NOT HANDLED PROPERLY. REFER TO THE MANUFACTURER’S DIRECTIONS FOR SAFE HANDLING.