Chlor. Off
High Salt/Amps
Is salt level
3400 or
below?
YES
NO
Reset
Chlorinator
diagnostics
Is voltage
reading above
35V?
YES
Verify correct
TCELL type in
configuration
4. Chlorinator OFF, High Salt/Amps
Test salt
level
Dilute salt level
and reset
average salt
Replace main
board
(see pg. 17)
NO
Does cell model
match
programming?
Change programming
to match installed
cell model
Reset average
salt, is error still
present?
Contact tech
support
(908)355.7995
YES
NO
Problem
solved
YES
NO