‘No Cell Power’ & Low Volts implies the chlorinator cycle has been interrupted due to
no/low voltage detected when the cell power relay was turned on. If the system
reports ‘CELL POWER ERROR’, replace the main board (see pg. 17).
Verify that 20-24VAC is present between the two
yellow wires (this represents the transformer output).
IF no/low volts, proceed to step 1B. IF voltage is
correct, jump ahead to step 1D
Disconnect the transformer input wires. On the PCB,
verify 120VAC between blue & white posts, & 120VAC
between violet & grey. IF no/low voltage, go to 1C. IF
voltage is correct, replace transformer (GLX-XFMR).
Test transformer output
Step 1A
Step 1B
Test transformer input
1. No Cell Power/Low Volts