EasyManuals Logo
Home>Hayward>Lighting Equipment>ProLogic

Hayward ProLogic Troubleshoot Manual

Hayward ProLogic
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
Air/Water Sensors: Resistance Chart
46
Ohms
Volts
Ohms
Volts
Ohms
Volts
Ohms
Volts
Ohms
Volts
Ohms
Volts
Ohms
Volts
Ohms
Volts
1
82,719
4.46 21
44,879
4.09 41
25,391
3.59 61
14,921
2.99 81
9,076 2.38
101
5,697 1.81
121
3,679 1.34
141
2,440 0.98
2
80,142
4.45 22
43,577
4.07 42
24,704
3.56 62
14,543
2.96 82
8,861 2.35
102
5,570 1.79
122
3,602 1.32
142
2,392 0.97
3
77,656
4.43 23
42,318
4.04 43
24,037
3.53 63
14,176
2.93 83
8,651 2.32
103
5,446 1.76
123
3,527 1.30
143
2,345 0.95
4
75,255
4.41 24
41,099
4.02 44
23,391
3.50 64
13,820
2.90 84
8,447 2.29
104
5,326 1.74
124
3,454 1.28
144
2,299 0.93
5
72,937
4.40 25
39,919
4.00 45
22,764
3.47 65
13,473
2.87 85
8,249 2.26
105
5,208 1.71
125
3,382 1.26
145
2,254 0.92
6
70,698
4.38 26
38,777
3.97 46
22,156
3.45 66
13,136
2.84 86
8,056 2.23
106
5,094 1.69
126
3,312 1.24
146
2,210 0.90
7
68,535
4.36 27
37,671
3.95 47
21,566
3.42 67
12,809
2.81 87
7,867 2.20
107
4,982 1.66
127
3,244 1.22
147
2,167 0.89
8
66,447
4.35 28
36,601
3.93 48
20,993
3.39 68
12,491
2.78 88
7,684 2.17
108
4,873 1.64
128
3,177 1.21
148
2,125 0.88
9
64,428
4.33 29
35,565
3.90 49
20,438
3.36 69
12,182
2.75 89
7,506 2.14
109
4,767 1.61
129
3,112 1.19
149
2,084 0.86
10
62,479
4.31 30
34,561
3.88 50
19,900
3.33 70
11,882
2.72 90
7,333 2.12
110
4,664 1.59
130
3,049 1.17
150
2,044 0.85
11
60,595
4.29 31
33,590
3.85 51
19,377
3.30 71
11,589
2.68 91
7,164 2.09
111
4,563 1.57
131
2,987 1.15
151
2,005 0.84
12
58,774
4.27 32
32,648
3.83 52
18,870
3.27 72
11,305
2.65 92
6,999 2.06
112
4,464 1.54
132
2,926 1.13
152
1,966 0.82
13
57,014
4.25 33
31,737
3.80 53
18,377
3.24 73
11,029
2.62 93
6,839 2.03
113
4,368 1.52
133
2,867 1.11
153
1,929 0.81
14
55,313
4.23 34
30,853
3.78 54
17,899
3.21 74
10,761
2.59 94
6,683 2.00
114
4,274 1.50
134
2,809 1.10
154
1,892 0.80
15
53,669
4.21 35
29,998
3.75 55
17,435
3.18 75
10,500
2.56 95
6,530 1.98
115
4,183 1.47
135
2,752 1.08
155
1,856 0.78
16
52,078
4.19 36
29,169
3.72 56
16,985
3.15 76
10,246
2.53 96
6,382 1.95
116
4,094 1.45
136
2,697 1.06
156
1,821 0.77
17
50,541
4.17 37
28,365
3.70 57
16,548
3.12 77
9,999 2.50 97
6,238 1.92
117
4,007 1.43
137
2,643 1.05
157
1,787 0.76
18
49,054
4.15 38
27,587
3.67 58
16,123
3.09 78
9,758 2.47 98
6,097 1.89
118
3,922 1.41
138
2,591 1.03
158
1,753 0.75
19
47,616
4.13 39
26,832
3.64 59
15,711
3.06 79
9,525 2.44 99
5,960 1.87
119
3,839 1.39
139
2,539 1.01
159
1,720 0.73
20
46,225
4.11 40
26,100
3.61 60
15,310
3.02 80
9,297 2.41
100
5,827 1.84
120
3,758 1.37
140
2,489 1.00
160
1,688 0.72
Use the following chart to determine the reported temperature of a sensor based on
either resistance (with sensor disconnected) or DC voltage (with sensor connected):

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward ProLogic and is the answer not in the manual?

Hayward ProLogic Specifications

General IconGeneral
BrandHayward
ModelProLogic
CategoryLighting Equipment
LanguageEnglish

Related product manuals