Chlorine Output & Salt Levels
48
1. The cycle time (reversal of polarity) is 180 minutes (3 hrs). When you set the
Desired Output %’ through the control system it sets the level of chlorination
based on the three hour cycle. 50% represents the factory default. The following
represents an example of how the system reacts to percentage output:
3 hr cycle: If the output is set at 50% and the total time for operation is 9 hrs,
the salt cell will operate (and produce chlorine) for 50% (1.5 hrs) of each 3 hr.
cycle for a total of 4.5 hrs
2. Super-chlorinate is an additional option to use in order to ‘catch up’ in chlorine
production when making adjustments to the desired output level. To activate, press
the menu button until the ‘Settings Menu’ appears. Press the right arrow until ‘Super
Chlorinate Off’ appears; press the (+) to change it from ‘Off’ to ‘On’. This will
cause the system to produce chlorine at 100% output for 24 hours (unless the Super
Chlorination duration was changed previously in the configuration. Once the Super
Chlorinate function has concluded the chlorine output percentage will once again
drive the chlorine production.