EasyManuals Logo
Home>HELLER>Air Conditioner>HPAC10

HELLER HPAC10 User Manual

HELLER HPAC10
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Never immerse the appliance in water or any other liquid.
Special Recommendations
Ensure that the appliance is positioned on a flat, large, dry surface without any obstacles nearby. A
minimum distance from furniture and walls is 50cm in all directions.
The plug should be easily accessible.
In order to maintain the function of the compressor, the appliance should always be in a vertical
position.
Do not use the appliance near gas or other flammable liquids.
Do not block the air outlet or the air inlet ventilation.
Do not use spray (insecticides, paint) or any other flammable products near the appliance as the
plastic may become deformed. The unit may also sustain electrical damage.
Power Source
The plug should be well secured and not damaged.
Do not plug in the appliance with an adaptor.
Plug into the wall socket before switching on the appliance, and then press the ON/OFF button.
THE MANUFACTURER WILL NOT ASSUME ANY RESPONSIBILITY FOR NON COMPLIANCE OF INSTRUCTIONS.
KEEP THIS USER MANUAL FOR FUTURE REFERENCE.
Installation
Location
Place the unit on a flat, dry surface. Leave at least 50cm of space around the unit, as per below diagram 1.
DIA 1
50cm

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HELLER HPAC10 and is the answer not in the manual?

HELLER HPAC10 Specifications

Operating Environment IconOperating Environment
permissible excessive operating pressure (suction)1.5 MPa
permissible excessive operating pressure (discharge)5.5 MPa
maximum allowable pressure (low pressure side)1.7 MPa
maximum allowable pressure (high pressure side)5.5 MPa
Power IconPower
power supply220-240 V / 50 Hz
rated input (cooling)1050 W
Performance IconPerformance
cooling capacity2.93 kW
air flow360 m3/h
noise55 dB(A)
Refrigerant IconRefrigerant
refrigerant typeR410a
refrigerant charge500 g
Weight and Dimensions IconWeight and Dimensions
net weight25 kg
gross weight30 kg
dimensions (WxHxD)433 x 795 x 330 mm