7. Route the cables through the bottom cable hole, or
the side cable hole of the junction box.
8. Combine the junction box cover with its body.
Figure 2-7 Fix the Junction Box Cover back to its
Body
9. Repeat the step 5 and 6 of 2.1.1 Ceiling/Wall
Mounting without Junction Box to complete the
installation.
2.2 Installation of Type II Camera
2.2.1 Ceiling/Wall Mounting without Junction Box
Steps:
1. Paste the drill template (supplied) to the place
where you want to install the camera.
2. Drill the screw holes according to the drill template,
and the cable hole (optional) on the ceiling.
Ø 68 mm
( 2.68" )
Ø 55 mm
( 2.17" )
Template
Side Opening
Screw Hole
Screw Hole
Screw Hole
Ø 18 mm
( 2.68" )
Figure 2-8 Drill Template
Note:
Drill the cable hole in the center of the drill template,
when adopting ceiling outlet to route the cable.
3. Route the cables through the cable hole (optional)
or the side opening.
4. Fix the camera to the ceiling with supplied screws.
Figure 2-9 Fix the Camera to the Ceiling
Note:
The supplied screw package contains self-tapping
screws, and expansion bolts.
For cement wall/ceiling, expansion bolts are
required to fix the camera. For wooden
wall/ceiling, self-tapping screws are required.
5. Connect the corresponding power cord, and video
cable.