Chapter 3 Grounding
3.1 Connecng the Grounding Cable
Grounding is used to quickly release overvoltage and overcurrent induced by lightening for switch,
and to protect personal safety. Select the appropriate grounding method according to your needs.
3.1.1 With Grounding Bar
If a grounding bar is available at the installaon site, follow the steps below.
Steps
1. Connect one end of the grounding cable to the binding post on the grounding bar.
2. Connect the other end of the grounding cable to the grounding terminal of the device and
x
the screw.
Figure 3-1 Grounding with Grounding Bar
3.1.2 Without Grounding Bar
If there is no grounding bar but the earth is nearby and the grounding body is allowed to be
buried, follow the steps below.
Steps
1. Bury an angle steel or steel pipe (≥ 0.5 m) into the mud land.
2. Weld one end of the grounding cable to the angle steel or steel pipe and embalm the welding
point via
electroplang or coang.
3. Connect the other end of the grounding cable to the grounding terminal.
100 Mbps PoE Switch Quick Start Guide
6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-3E1X05P Series and is the answer not in the manual?

HIKVISION DS-3E1X05P Series Specifications

General IconGeneral
BrandHIKVISION
ModelDS-3E1X05P Series
CategorySwitch
LanguageEnglish

Related product manuals