Redundant coupling
24
3.2
Configuring the redundant coupling
Redundancy L2E
Release
4.1
03/08
3.2 Configuring the redundant
coupling
3.2.1 STAND-BY switch
The Switches have a STAND-BY switch for selecting between the main
coupling and the redundant coupling. Depending on the Switch, this switch is
a DIP switch or a software switch (Redundancy:Ring/Network
Coupling dialog), or you can use a switch to select one of the two options.
Depending on the Switch used, you choose between the main coupling and
the redundant coupling (see table 6).
Switch STAND-BY switch
RS2-../.. DIP switch
RS2-16M DIP switch
RS20/RS30/RS40 Can be switched between DIP switch and software switch
MICE/PowerMICE Can be switched between DIP switch and software switch
MS 20/MS 30 Can be switched between DIP switch and software switch
RSR20/RSR30 Software switch
MACH 1000 Software switch
MACH 3000/MACH 4000 Software switch
Table 5: STAND-BY switches of the Switches