Page #27 background image
24
WR6CE User Manual
Serial Protocol
Serial port status
The device can receive the serial port command sent by the external controller or OPS of the
device.
Refer to the following table for the specic command protocol:
1. Baud rate: 9600 2. Control section: PC → The device 3. Response section: Android
→ PC
 
Protocol
header
Length Command code ID Data Verify
Protocol
tail
Screen
on/off
On
PC to
device
DD FF 00 07 C1 31 00 00 01 00 F6 BB CC
On
Device to
PC
AB AB 00 07 C1 31 00 00 01 00 F6 CD CD
Off
PC to
device
DD FF 00 07 C1 31 00 00 01 01 F7 BB CC
Off
Device to
PC
AB AB 00 07 C1 31 00 00 01 01 F7 CD CD
Current
Signal
Source
Query
PC to
device
DD FF 00 06 C1 1A 00 00 01 DC BB CC
Device to
PC
AB AB 00 09 C1 1A 00 00 01
XX XX
XX
XX CD CD
Remark
Data: XX XX XX
05 03 02: OPS
05 03 00: Front HDMI
05 03 01: Side HDMI
05 03 03: Type-C
05 03 04: DP
Software
Version
Query
PC to
device
DD FF 00 06 C1 1B 00 00 01 DD BB CC
Device to
PC
AB AB 00 09 C1 1B 00 00 01
XX XX
XX
XX CD CD
Remark
The rst XX is the Year.
The second XX is the Month.
The third XX is the Day.
Set Time
(Y/M/D)
PC to
device
DD FF 00 09 C1 1C 00 00 01
XX XX
XX
XX BB CC
Device to
PC
AB AB 00 09 C1 1C 00 00 01
XX XX
XX
XX CD CD
Remark
The rst XX is the Year.
The second XX is the Month.
The third XX is the Day.
If set failures, these three XX return FF.
6. Serial Protocol