EasyManuals Logo
Home>Hitachi>Heat Pump>RAS-3WHVRP

Hitachi RAS-3WHVRP Technical Catalogue

Hitachi RAS-3WHVRP
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
2 General data
ERP performance data
TCGB0123 rev.2 - 10/2019
26
2.2.2.4 ERP additional data - YUTAKI S
RAS-(2-3)WHVRP + RWM-(2.0-3.0)NRE(-W)
Model
HP 2.0 HP 2.5 HP 3.0 HP
Outdoor unit RAS-2WHVRP RAS-2.5WHVRP RAS-3WHVRP
Indoor unit RWM-2.0NRE(-W) RWM-2.5NRE(-W) RWM-3.0NRE(-W)
Electrical power input in stand-by mode (Psb) W 11.9 11.9 11.9
Electrical power input in thermostat-OFF mode (Pto) W 0.0 0.0 0.0
Electrical power input in OFF mode (Poff) W 11.9 11.9 11.9
Electrical power input in crankcase heater mode (Pck) W 0.0 0.0 0.0
Sound power level of indoor unit (L
WA
) dB(A) 37 37 37
Capacity control mode - Variable (Inverter)
Integrated supplementary heater kW 3.0 3.0 3.0
Nominaloutdoorairow m
3
/h 2436 2436 2682
2.2.2.5 ERP additional data - YUTAKI S COMBI
RAS-(2-3)WHVRP + RWD-(2.0-3.0)NRW(S)E-(200/260)S(-K)(-W)
Model
HP 2.0 HP 2.5 HP 3.0 HP
Outdoor unit RAS-2WHVRP RAS-2.5WHVRP RAS-3WHVRP
Indoor unit
RWD-2.0NRW(S)E
(200/260)S(-K)(-W)
RWD-2.5NRW(S)E
(200/260)S(-K)(-W)
RWD-3.0NRW(S)E
(200/260)S(-K)(-W)
Electrical power input in stand-by mode (Psb) W 11.9 11.9 11.9
Electrical power input in thermostat-OFF mode (Pto) W 0.0 0.0 0.0
Electrical power input in OFF mode (Poff) W 11.9 11.9 11.9
Electrical power input in crankcase heater mode (Pck) W 0.0 0.0 0.0
Sound power level of indoor unit (L
WA
) dB(A) 37 37 37
Capacity control mode - Variable (Inverter)
Integrated supplementary heater kW 3.0 3.0 3.0
Nominaloutdoorairow m
3
/h 2436 2436 2682
2.2.2.6 ERP additional data - YUTAKI M
RASM-(2-3)VRE
Model HP
2.0 HP 3.0 HP
RASM-2VRE RASM-3VRE
Electrical power input in stand-by mode (Psb) W 11.9 11.9
Electrical power input in thermostat-OFF mode (Pto) W 0.0 0.0
Electrical power input in OFF mode (Poff) W 11.9 11.9
Electrical power input in crankcase heater mode (Pck) W 0.0 0.0
Sound power level of outdoor unit (L
WA
) dB(A) 61 69
Capacity control mode - Variable (Inverter)
Integrated supplementary heater kW No
Nominaloutdoorairow m
3
/h 2436 2682

Table of Contents

Other manuals for Hitachi RAS-3WHVRP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi RAS-3WHVRP and is the answer not in the manual?

Hitachi RAS-3WHVRP Specifications

General IconGeneral
BrandHitachi
ModelRAS-3WHVRP
CategoryHeat Pump
LanguageEnglish

Related product manuals