ENGLISH
3.2 ERP PERFORMANCE DATA
3.2.1 General considerations
• This appliance must be installed, maintained and dismantled by professionals. Do not pour contained refrigerant into the
atmosphere since this refrigerant uid is a uorinated greenhouse gas regulated under European Regulation (EU) No 517/2014.
• Data with the mark (*) corresponds to the “Energy efciency contribution (η
S
)” due to the use of temperature control.
OTC control (Factory-supplied)
Wired room thermostat (PC-ARFHE) 7E543002(*)
Wireless room thermostat (ATW-RTU-04) 7E543003
Wired room sensor (ATW-ITS-01) 7E549932
Temperature control class II Temperature control class VI
Energy efciency contribution +2% Contribution to the nominal energy efciency +4%
(*) Factory supplied in case of Yutaki S, SC and S80 DHW Tank
• Data between brackets corresponds only to heating and cooling models (“Cooling kit” accessory needed).
3.2.2 General ERP data for space heaters
3.2.2.1 ERP data - YUTAKI S
AVERAGE climate
RAS-(2-3)WHVNP + RWM-(2.0-3.0)NE
Model
Outdoor unit RAS-2WHVNP RAS-2.5WHVNP RAS-3WHVNP
Indoor unit RWM-2.0NE RWM-2.5NE RWM-3.0NE
Water outlet temperature 35ºC 55ºC 35ºC 55ºC 35ºC 55ºC
Product
description
Air to water heat pump -
Yes
Heat pump combination heater -
No
Low temperature heat pump -
No
Complementary heater -
Yes
Design capacity (P
DESIGN
) kW
4.0 4.0 6.0 5.0 7.0 6.0
Nominal energy efciency (η
S
) %
189 (194) 137 (140) 177 (180) 130 (132) 165 (167) 125 (127)
Nominal energy class -
A+++ A++ A+++ A++ A++ A++
Data for Packaged Fiche:
Energy efciency with OTC control (η
S
) (*) %
191 (196) 139 (142) 179 (182) 132 (134) 167 (169) 127 (129)
Energy class with OTC control -
A+++ A++ A+++ A++ A++ A++
Energy efciency with thermostats/sensors (η
S
) (*) %
193 (198) 141 (144) 181 (184) 134 (136) 169 (171) 129 (131)
Energy class with thermostats -
A+++ A++ A+++ A++ A++ A++
Supplementary capacity (P
SUP
) kW
0.0 0.6 0.3 0.7 0.6 0.8
Type of energy used -
Electricity
Declared capacity (Pdh) and coefcient of performance (COP
d
) at partial load under the following outdoor temperatures:
Outdoor temperature (Tj) = -7ºC
Pdh kW
3.54 3.50 4.95 4.42 5.90 5.10
COP
d
-
3.20 2.20 2.70 1.85 2.50 1.84
Outdoor temperature (Tj) = +2ºC
Pdh kW
2.15 2.10 3.01 2.69 3.59 3.10
COP
d
-
5.20 3.73 4.60 3.45 4.40 3.20
Outdoor temperature (Tj) = +7ºC
Pdh kW
1.70 1.60 1.90 1.84 2.31 2.00
COP
d
-
6.05 4.40 6.00 4.20 5.35 4.45
Outdoor temperature (Tj) = +12ºC
Pdh kW
1.75 1.60 1.80 2.06 2.10 2.30
COP
d
-
6.25 5.00 7.20 6.90 6.15 5.96
Outdoor temperature (Tj) = Bivalent
temperature (T
biv
)
Pdh kW
3.54 3.50 4.95 4.42 5.90 5.10
COP
d
-
3.20 2.30 2.70 1.85 2.50 1.84
Outdoor temperature (Tj) = Limit operation
temperature (TOL)
Pdh kW
4.00 3.40 5.30 4.30 6.40 5.20
COP
d
-
2.75 2.10 2.50 1.80 2.30 1.65
Bivalent temperature (T
biv
) ºC
-7 -7 -7 -7 -7 -7
Limit operation temperature (TOL) ºC
-10 -10 -10 -15 -10 -15
Water limit operation temperature (WTOL) ºC
55 55 55 55 55 55
Degradation coefcient (Cdh) -
0.9 0.9 0.9 0.9 0.9 0.9
Annual energy consumption (Q
HE
) kW·h
1719 (1675) 2341 (2298) 2569 (2525) 3110 (3066) 3286 (3242) 3714 (3671)
GENERAL DATA
PMML0335A rev.1 - 04/2016
19