AC APPLICATIONS
Before connecting an appliance or power cord to the generator:
Make sure that
it
is
in
good working order. Faulty appliances or
power cords can create a potential for electrical shock.
If an appliance begins to operate abnormally, becomes sluggish or
stops suddenly, turn
it
off
immediately. Disconnect the appliance,
and determine whether
the
problem is the appliance, or if the rated
load capacity of the generator has been exceeded.
0
Make sure that the electrical rating
of
the tool
or
appliance does not
exceed
that
of the generator. Never exceed the maximum power
rating of the generator. Power levels between rated and maximum
may be used for no more than
30
minutes.
I
NOTICE
I
Substantial overloading will switch
off
the
AC
circuit breaker.
Exceeding the time limit for maximum power operation or slightly
overloading the generator may not switch the
AC
circuit breaker
OFF,
but will shorten the service life of the generator.
Limit operation requiring maximum power to
30
minutes.
Maximum power is:
EG1400X: 1.4 kVA
EG2500X: 2.5 kVA
For continuous operation, do not exceed the rated power.
Rated power is:
EG1400X: 1.2 kVA
EG2500X: 2.3 kVA
The total power requirements (VA) of all appliances connected must
be considered. Appliance and power tool manufacturers usually list
rating information near the model number or serial number.
17