FUEL SEDIMENT CUP CLEANING
The sediment cup prevents dirt or water which may be
in
the fuel tank
from entering the carburetor. If the engine has not been run for
a
long
time, the sediment cup should be cleaned.
1.Turn the fuel valve lever to
OFF.
Remove the sediment cup and
O-ring.
2.Clean the sediment cup and O-ring
in
nonflammable or high flash
point solvent.
3.
Reinstall the O-ring and sediment cup.
4.
Turn
the
fuel valve
ON
and check for leaks.