Part No: 4417341 Revision 10 Installation Manual 32
954 SmartServo FlexLine
Power Supply (CAN-PSS)
Connect the power supply to either:
• DC: 24 - 65 Volt
• AC: 65 - 240 Volt
NOTE:
The DC polarity is not critical.
NOTE:
Disconnection from the supply source needs to be performed externally with an easy
accessible and clearly marked switch or circuit breaker as disconnecting device and shall
disconnect all current carrying conductors.
Cable Specifications
Label
Parameters
00. Vin-a/L
24-65 Vdc -15/+10%
65-240 Vac -15/+10%
50/60 Hz ± 10% Automatic selection
01. Vin-b/N
Enraf Fieldbus (Bi Phase Mark) (CAN-BPM)
Cable specifications
Type
Twisted pair; R
max
= 200 Ohm /line, C
max
= 1 μF.
Maximum length
10 km
Cable specifications
Type
Suitable for the 954 SmartServo FlexLine power rating, and approved for
use in hazardous areas
Label
Parameters
06.or 08 TL1
1200/2400/4800 bps
Selection by software
07.or 09 TL2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell 954 SmartServo FlexLine and is the answer not in the manual?

Honeywell 954 SmartServo FlexLine Specifications

General IconGeneral
BrandHoneywell
Model954 SmartServo FlexLine
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals