Honeywell Portable Generator Service Manual www.honeywellgenerators.com 6-1
6: SERVICE REPAIR TIME ANALYSIS & FLAT RATE SCHEDULE
Repair times represent generally accepted intervals for conducting a repair. Service centers are always advised to pro-
vide feedback during the warranty claim process if additional time may be needed due to unforseen circumstances.
Operation
HW4000
(min.)
HW5500
(min.)
HW5500E
(min.)
HW6200
(min.)
HW7500E
(min.)
ELECTRICAL
Alternator Assembly 60 60 60 60 60
Capacitor 30 30 30 30 30
Flash the Field 30 30 30 30 30
Ignition Coil 50 50 50 50 50
Isolator 40 40 40 40 40
Oil Alert3030303030
Pull Start Assembly 30 30 30 30 30
Receptacles / Ports / Switches/Breakers 30 30 30 30 30
Starter (electric start models only) -- -- 40 -- 40
Starter Solenoid -- -- 30 -- 30
ENGINE
Air Filter Assembly 30 30 30 30 30
Carburetor 30 30 30 30 30
Choke Assembly 50 50 50 60 60
Crankcase Gasket 70 70 70 70 70
Engine 120 120 120 120 120
Governor Assembly 50 50 50 60 60
FUEL & EXHAUST
Fuel Cock 30 30 30 30 30
Fuel Gauge 30 30 30 30 30
Fuel Tank 50 50 50 50 50
Muffler 50 50 50 60 60
Muffler Gasket 50 50 50 60 60
MISC
Brackets / Hardware 30 30 30 30 30