Honeywell Portable Generator Service Manual www.honeywellgenerators.com 9-5
GENERATOR REAR HOUSING
9.5 GENERATOR REAR HOUSING
A—REAR HOUSING
B—BRUSH HOLDER ASSEMBLY
C—VOLTAGE REGULATOR ASSEMBLY
D—AC OUTPUT TERMINAL
E—GENERATOR END COVER
F—COOLING FAN
G—STATOR COVER
H—STATOR
I— ROTOR
Install appropriate rotor puller (special tool),
hold flywheel, and torque puller to 45-50 N•m
(33.2-36.9 lb. ft.; 4.6-5.1 kg-m).
If torquing rotor puller does not free rotor from
crankshaft, tap end of puller with brass ham-
mer to loosen rotor. Use oil before replacing.
NOTICE
Rotor can become damaged if not properly
supported. Place wooden block and rag
underneath rotor for support.
To prevent eye injury, always wear
safety glasses or goggles when
striking end of rotor puller.