• the isolating switch is easily accessible by the custome
EN-27
r
Before locating the fixing brackets
The unit should be placed on a stable, smooth surface (use the packaging). Do not
apply force onto the controls protruding from the hob.
Adjusting the bracket position
Fix the hob on the work surface by screw 4 brackets on the bottom case of hob
(see picture) after installation.
A B C D
Screw Bracket Screw hole Bottom case
Cautions
1. The induction hotplate must be installed by qualified personnel or technicians.
We have professionals at your service. Please never conduct the operation by
yourself.
2. The hob will not be installed directly above a dishwasher, fridge, freezer,
washing machine or clothes dryer, as the humidity may damage the hob
electronics
3.The induction hotplate shall be installed such that better heat radiation can be
ensured to enhance its reliability.
4. The wall and
induced heating zone above the table surface shall withstand heat.
5. To avoid any damage, the sandwich layer and adhesive must be resistant to
heat.
Connecting the hob to the mains power suppl
EN-28
y
This hob must be connected to the mains power supply only by a suitably qualified person.
Before connecting the hob to the mains power supply, check that:
1. the domestic wiring system is suitable for the power drawn by the hob.
2. the voltage corresponds to the value given in the rating plate
3. the power supply cable sections can withstand the load specified on the rating plate.
To connect the hob to the mains power supply, do not use
adapters, reducers, or branching
devices, as they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned so that its
temperature will not exceed 75˚C at any point.
Check with an electrician whether the domestic wiring system is suitable without
alterations. Any alterations must only be made by a qualified electrician.
The power supply should be connected in compliance with the relevant standard,
or a single-pole circuit
breaker. The method of connection is shown below.
• If the cable is damaged or to be replaced, the operation must be carried out the
by after-sale agent with dedicated tools to avoid any accidents.
• If the appliance is being connected directly to the mains an omnipolar
circuit-breaker must be installed with a minimum opening of 3mm between
contacts.
• The installer must ensure that the correct electrical connection has been made
and that it is compliant with safety regulatio
ns.
• The cable must not be bent or compressed.
• The cable must be checked regularly and replaced by authorised technicians
only.