r:-··
1
••
Model
4328A
3-47.
On
the
1
and
3m
ohm
ranges,
currents
flow-
ing
in
the
current
leads
are
150
mA
and
50 rnA
respec-
tively
large
compared
to
other
ranges.
Moreover,
the
voltmeter
sechon
has
very
high
sensitivity,
so
that,
if
a
conductor
surface
is
placed
near
and
parallel
to
the
current
loop,
large
errors
may
result
due
to
coupling
between
the
current
loop,
the
conductor
and
the
voltage
terminals.
Therefore,
at
1
and
3m
ohm
range,
the
probes
and
their
cables
(i.e.
the
part
be-
tween
the
connector
and
the
tip
of
probe)
must
be
placed
lOcm
or
more
away
from
the
conducting
sur-
face
or
the
probes
must
be
placed
perpendicularly
to
the
conductor
face
..
3-48.
A
4-
terminal
measurement
ts
a
method
by
which
resistance
is
accurately
measured
by
removing
the
effect
of
thermal
emf
and
Lead
wire
resistance.
If
a
4-termmal
device
is
measured
with
the
4-terminal
method
(Figure
3-9,
a),
the
reading
of
the
indtcating
meter
will
be
an
Rx
which
is
accurate.
However,
when
measuring
resistance
by
ustng
only
two
terminals
of
a
4-terminal
device
(as
shown
in
Figure
3-9,
b)
the
meter
will
show
the
resistance
of
Rx
+
2Re.
Thus
an
error
of
2Re/Rx
results
in
this
instance.
If
Rx
is
much
larger
than
Re
(Rx/Re>
1000),
the
error
wtll
be
withm
specifications
(±2%)
even
if
measuring
resist-
ance
wtth
the
method
shown
in
Figure
3-9b.
3-49.
CHANGING
TEST
LEAD
LENGTH.
3-50.
The
values
in
Table
3-2
are
given
for
wire
lengths
from
the
tip
of
test
lead
plug
to
the
other
end
of
lead
wire,
and
are
maxtma
for
a
single
lead.. Note
that
BOTH
the
resistance
of
lead
wire
AND
the
wire
length
must
be
kept
within
the
values
shown
in
Table
3-2
at
the
same
time..
Further
it
is
recommended
that
the
4
lead
wires
be
used
in
a
bundle
as
far
as
is
possible
..
The
wire
length
and
wire
quality
of
the
other
two
kinds
of
probes
should
not
be
changed.
4-TERMINAL
DEVICE
VOLTAGE
TERMINAL
(a)
CURRENT
TERMINAL
s
Rx
MEASURED RESISTANCE.
Section
III
Paragraphs
3-47
to
3-50
Table
3-2.
Maximum
Values
of
Resistance
and
Length
of
Lead
Wire
Range
Lead
Wire
Lead
Wire
(ohms)
Resistance
Length
(em)
(ohms)
0.001
0.002-0.02*
40
0.003
0
06
60
0.01
0.2
100
0.03
0.6
200
0.1
2
200
0.3
6 200
1
20
200
3 20 200
10
20 200
30
20
200
100
20 200
Mimmum
to
maximum
value
shown.
4-
TERMINAL
DEVICE
.~
~
1
VOLTAGE
:TERMINAL
I
\
I
CURRENT
I
TERMINAL
I
r
I
I
(b)
Re
RESISTANCE OF
LEAD
OR
TERMINAL.
Ftgure
3-9.
4-Terminal
Device
Measurement
3-7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 4328A and is the answer not in the manual?

HP 4328A Specifications

General IconGeneral
BrandHP
Model4328A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals