Section
V
Paragraphs
5-11
to
5-22
5-11.
MAINTENANCE
5-12.
Service
information
m
the
form
of
trouble-
shooting,
waveforms,
schematics
and
component
loca-
tions
are
given
m
Section
VIII.
Also,
an
overall
sys-
tem
block
diagram
is
included
which
contains
keyed
numbers
correspondmg
to
the
test
points.
5-13.
4328A
PERFORMANCE
CHECKS
5 -14..
The
performance
checks
presented
here
are
front
panel
operations
designed
to
compare
the
Model
4328A
wlth
its
published
specifications
These
opera-
tions
should
be
conducted
before
any
attempt
is
made
at
instrument
calibration
or
adjustment
During
per-
formance
tests,
periodically
vary
the
Une
voltage
sup-
plied
totheModel4328A,
ยฑ:1000on
eitherll5
or230
V
operation
A
1/4
hour
warm-up
period
should
be
al-
lowed
before
these
tests
are
conducted.
5-15.
MECHANICAL
METER
ZERO.
5-16.
If
necessary,
mechanically
zero
the
meter
movement
as
follows.
a..
With
instrument
turned
off,
rotate
meter
adjust-
ment
screw
clockwise
until
pointer
approaches
zero
mark
from
the
left.
b.
Continue
rotatmg
clockwise
until
pointer
com-
cides
with
zero
mark.
If
pointer
overshoots,
continue
rotating
adjustment
screw
clockwise
until
pointer
once
again
approaches
zero
mark
from
the
Left.
c.
Rotate
adjustment
screw
about
three
degrees
counterclockwise
to
disengage
itfrom
the
meter
suspension
5 -17..
LINEARITY
CHECK
a..
Attach
the
Model16005A
probe
to
the
4328A
and
set
the
range
switch
to
100R
Table
5-2.
Linearity
Test
Standard
HP
Model
HP
Model
Decade
4328A
4328A
Resistor
Meter
Range
Settmgs
Readings
Settings
on
0
10
8 -
12
20 18 -
22
30
28 -
32
40 38 -
42
50 48 -
52
won
60
58 -
62
70
68
-
72
80
78
-
82
90 88 -
92
100
98
- 102
5-2
Model
4328A
b..
Connect
the
Model
4328A
probe
to
the
Decade
Resistance
Box
(
YEW
Type
2792
or
GR
Model
1432T)
c..
Switch
the
Decade
Resistor,
providing
0
to
1
00&1,
in
10n
steps.
d..
The
Model4328A
should
read
as
shown
in
Table
5-2.
5-18
FULL
SCALE
CHECK
a
Attach
the
Model
16007AiB
Test
Lead
to
the
Model
4328A.
b
Connect
the
Test
Leads
to
Standard
Resistor
of
0
..
001
to
lOOn
and
check
the
full
scale
readings
of
the
Model
4328A.
The
Meter
should
read
as
shown
in
Table
5-3.
5-19.
COVER
REMOVAL
AND
REPLACEMENT
5-20.
The
side
covers
can
be
removed
and
replaced
independently
of
the
top
and
bottom
cove
r.s.
Each
side
cover
1s
held
in
place
by
four
screws
retamed
by
nuts
whlch
are
fastened
to
the
side
frames.
5-21.
TOP
COVER
REMOVAL
a.
At
the
rear
of
the
instrument,
remove
the
screw
that
retams
the
cover.
b.
Grasp
the
cover
from
the
rear,
and
slide
it
back
1 ยท 2 inch..
Then
tilt
forward
edge
of
the
cover
upward
and
hft
the
cover
from
the
instrument
..
5-22
TOP
COVER
REPLACEMENT
a.
Rest
the
cover
flat
on
the
cast
guides
projectlng
mward
near
the
top
of
each
side
frame.
Table
5-3.. FuLl
Scale
Test
Standard
HP
ModeL
HP
Model
Resistor
4328A
4328A
Meter
Range
Readings
Settings
0
..
001
f.!
0. 00098 -
0
..
00102
r2
0
..
001 n
t ( 0
003 0
00294
-
0
..
00306
0
..
003)
0
..
01
0.0098
-
0
..
0102
0
..
01
0.03
0.0294
-
0.0306
0
..
03
0
..
1
0
..
098
-
0.102
0. 1
0
..
3
0.294
-
0
..
306 0
..
3
1
0
..
98
-
1.
02
1
3
2.
94
-
3.06
3
10
9
..
80
-
10
..
2
10
30 29
..
4
-
30.6
30
100
98.0
-
102
0
100
*
YEW
TYPE
2872
only.