AlphaServer ES47/ES80/GS1280 Server Management CLI Reference
3.63 show power
Displays the status of power supplies, fans, temperatures and voltages. The VRM status for
dual-processor modules are listed under the Power Supply Column.
By default, the entire hardware status is shown in summary:
P Current status Pass
W Current status Warning
F Current status Fail (or Off if power supply)
D Current status Disabled for RIMM
p Past status Pass (currently not powered on)
w Past status Warning
f Past status Fail (currently not powered on)
d Past status Disabled for RIMM
? Status unknown (typically status not obtained due to I
2
C error)
. Not present or not applicable
UNK Unknown status (typically status not obtained due to I
2
C error)
Syntax
show power
[-cabinet <cabinet> -drawer <drawer> [SBB, PCI, DUO<n>]] [-detail]
Arguments
SBB The entire system building block and its power supply subsystem.
PCI The PCI drawer by cabinet and drawer number.
DUO<n> The dual-processor module by cabinet and drawer number. n refers to the
processor module within the 8P drawer and ranges from 0 to 3.
Options
-cabinet <cabinet> Cabinet number in hex. If this qualifier is not used, all
cabinets are shown.
-drawer <drawer> Drawer number in hex. If this qualifier is not used, all
drawers are shown.
-detail Describe each item in detail.
Examples
1. Show the system environment summary while the system is on, then off.
MBM> sh power
Cabinet OCP switch position: ON
Cab Drw Type Power Fan WPI/SDI PS/VRM Temperature( C) Voltage
0123456 0123 0123456789ABC 0 1 2 3
0 0 SBB ON PP..... P... P.P.......... 29.0 23.0 .... .... P
0 0 DUO0 ON ....... .... PPPPP...PPPPP 22.0 31.1 28.1 .... P
0 0 DUO1 ON ....... .... PPPP....PPPPP 26.0 31.6 30.1 .... P
0 0 DUO2 ON ....... .... .PPPPP..PPPPP 24.0 31.1 31.6 .... P
0 1 SBB ON PP..... P... PPP.......... 30.5 23.5 .... .... P
0 1 DUO0 ON ....... ... PPPPP...PPPPP 22.0 30.6 30.1 .... P
3-106