Commands
3.42 set dial
Sets the modem dial string. The dial string is the target phone number and any appropriate
modem commands required by the target. It is nonvolatile across system resets and power
cycles. The maximum string length is 63 characters. The dial string is sent to the modem before
the alert string.
Because modem commands disallow mixed cases, all alphabetic characters in the dial string are
converted to uppercase.
Syntax
set dial
[<dial_string>]
Argument
dial_string The ASCII string that is sent to the modem when an alert condition is
triggered. If no argument is given, the dial string is erased.
Options
None
Example
Set up the dial string to call a numeric paging service.
MBM> set dial atdt9,15085551212#;
MBM>
See Also
set alert, enable alert, test alert, show modem