Table 13 HP array event information packet (EIP) types (continued)
DescriptionTitleCode
A change in system time occurred.Executive Services System Time Change0D
A Storage System Management Interface entity was
created or deleted.
Storage System Management Interface Entity
Creation or Deletion
0E
An attribute of a Storage System Management
Interface entity has changed.
Storage System Management Interface Entity Attribute
Change
0F
A controller state change occurred.System Services HSV210 Controller State Change10
Status of a disk enclosure element has changed.Disk Enclosure Environmental Monitoring Unit
Services Status Change
11
Unexpected work was received from a physical disk
drive or the mirror port.
Fibre Channel Services Physical Disk Drive/Mirror
Port Unexpected Work Encountered
12
Summary of errors encountered while attempting to
access a physical disk drive, the mirror port, or a
Drive Enclosure Environmental Monitoring Unit.
Fibre Channel Services Physical Disk Drive/Mirror
Port/Drive Enclosure Environmental Monitoring Unit
Error Summary
13
A failure was detected during the execution of a
diagnostic.
Diagnostic Operations Generator Detected Failure14
An operation on a Disk Group has started or
completed.
Container Services Management Operation has
started or completed
15
An HSV210 controller has received a time report
message.
Data Replication Manager Time Report16
A new device map has been generated on a Fibre
Channel port.
Fibre Channel Services Fibre Channel Port Loop
Config
17
A Redundant Storage Set state change occurred.Storage System State Services Redundant Storage
Set State Change
18
Status of a System Data Center element has changed.System Data Center Services Status Change19
A code load operation has occurred.System Services Code Load Operation Update1A
An HSV210 controller operation was terminated due
to an unrecoverable event detected by either software
Fault Manager Termination Event1C
or hardware or due to an action initiated via the
Storage System Management Interface.
An HSV210 controller operation was terminated due
to an unrecoverable event detected by either software
Fault Manager Termination Event (old Termination
Event Information Header)
1D
or hardware or due to an action initiated via the
Storage System Management Interface.
General Storage System state information to be
reported.
General Storage System State Services State
Information Event
1E
Coupled crash control codes
Table 14 HP array coupled crash control codes
DescriptionCode
Other controller should not perform a coupled crash.0
Other controller should perform a coupled crash.1
Event code types and descriptions 97