Enhancements in Release G.07.xx
Clarification of Time Zone Issue
Documentation for the HP ProCurve Gigabit LH-LC mini-GBIC is included in the installation
guide shipped with the optional HP ProCurve Switch GL Mini-GBIC Module and is also avail-
able on the HP ProCurve web site. See
“To Download Product Documentation:” on page 1.
For information on the above software enhancements and the other features available in
your switch, refer to the following publications:
• Management and Configuration Guide for the HP ProCurve Series 4100GL Switches,
Series 2600 Switches, and Switch 6108
• Access Security Guide for the HP ProCurve Series 4100GL Switches, Series 2600
Switches, and Switch 6108
The documentation mentioned above is also included on version 3.1 of the Product Documentation
CD-ROM, which is packaged with Series 4100GL switches shipped from the factory with release
G.07.2 x installed. You can also download the latest version of this documentation by visiting the HP
ProCurve web site. (See
“To Download Product Documentation:” on page 1.)
Clarification of Time Zone Issue
Starting with release G.05.xx , the method of configuring the Time Zone for TimeP or SNTP configu-
ration has been updated. Previous switch software, for all HP ProCurve switches, used positive time
offset values for time zones that are West of GMT and negative values for time zones that are East of
GMT. The standards indicate that time zones West of GMT should be designated by negative offset
values, and time zones East of GMT by positive values. Software version G.05.xx updates this
configuration method, but if you use the same values for indicating time zones as you did for previous
HP ProCurve switches, the time will be set incorrectly on your Series 4100GL switch. For example,
for previous HP ProCurve switches, the US Pacific time zone was configured by entering
+480. With
software version G.05.xx , the US Pacific time zone must now be configured by entering
-480.
7