Software Fixes
Release G.05.05
Crash (PR_5712) — The switch may crash with a message similar to: TLB Miss: Virtual
Addr=0x00000000 IP=0x8002432c Task='tSmeDebug'
Crash (PR_5745) — The switch may crash with a message similar to: Divide by Zero Error:
IP=0x801400c0 Task='sal_dpc_hi' Task ID=0x80616690 fp:0x00000000 sp:0x80616600
ra:0x800140060 sr:0x1000af01
Module (PR_5270) — Modules intermittently fail to boot during switch boot up.
Release G.05.05
Never released.
ARP (PR_4880) Changing the IP address of an interface does not flush the ARP entries
of the original IP address.
CLI/Timezone (PR_4992) The timezone changes made for PR_4524 are not transparent
to the end-user. On download of configuration, and during initialization, check for a transition
from code G.04.XX to G.05.XX and adjust configured timezone.
Configuration (PR_5025) — If the user enables portfast (that is, “spanning-tree 1-24 mode
fast”) the switch can't read the configuration during reload and stops the reload process.
Crash (PR_4892) — The switch may crash with a message similar to: -> Asserts in rv.cc
line 632
Crash (PR_5345) — The switch may crash with a message similar to: -> Assertion failed:0,
file drvmem.c, line 167
Crash (PR_5708) The switch may crash with a message similar to: -> Unalligned Access:
Virtual Addr=0x847e6929 IP=0x800270bc Task='tMsgCount' Task ID=0x804bf800
fp:0x804bf788 sp:0x804bf788 ra:0x800270b4 sr:0x1000af01
Crash (PR_5714) — The switch may crash with a message similar to: -> Bus error: HW
Addr=0x00000000 IP=0x002f6148 Task='mHttpCtrl'
Crash (PR_5715) — The switch may crash with a message similar to: -> Bus error: HW
Addr=0x00000000 IP=0x001429e0 Task='mChassCtrl' Task ID=0x16d0748
Crash (PR_5725) The switch may crash with a message similar to: -> Assertion failed:
nt, file dpc.c, line 169
Crash/Continuous Reboot (PR_5046) — Downloading a certain configuration will cause
the switch to bus error and reboot repeatedly.
GVRP (PR_4898) Upstream GVRP neighbor loses connectivity with downstream
neighbor after topology change.