EasyManuals Logo
Home>HP>Switch>ProCurve 4100GL Series

HP ProCurve 4100GL Series User Manual

HP ProCurve 4100GL Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Software Fixes
Release G.04.01
Release G.04.01
Never released.
Friendly Port Names
SSH Security (SSHv1)
RADIUS Security
Port-Access (802.1x) Security
QoS Priority
Rapid Spanning Tree (802.1W)
Performance enhancements to the message system has resulted in minimizing, or eliminating
the following types of messages from occurring in the event log and boot history:
ARL-1 problem detected. Please contact HP Support ARL-2 problem detected. Please contact
HP Support
NOTE: The startup-config file saved under version G.04.01, or later, is NOT backward-
compatible with previous software versions. The user is advised to save a copy of the pre-
04.01 startup-config file BEFORE UPGRADING to G.04.01 or greater, in case there is ever a
need to revert back to pre- 04.01 software. Instructions for saving a copy of the startup-config
file are found in the “Transferring Switch Configurations” section of Appendix A in the
Management and Configuration Guide (included on the Product Documentation CD-ROM
(PDF format)) that shipped with the switch.
CLI (PR_3521) The response to an incomplete trunk configuration command did not
produce the proper message “Incomplete input: Trunk.
CLI (PR_3750) — The crash history is lost after the “reload” command is performed from
the CLI.
Crash (PR_3736) — Switch may crash with a message similar to: ->Software exception at
bcm56xxDmaPoll.c:342--in 'sal_dpc_hi' ->Msg loss detected
Crash/Bus Error (VARIOUS) — A Get request of a specific long OID can result in a bus
error, an agent hang, or a switch crash with a message similar to: -> Software_exception at
svc_misc.s:379 -- in mCdpCtrl malloc_else_fatal() ran out of memory This crash has been
associated with the CERT SNMPv1 "Req-app" test suite.
Flow Control (PR_3026) — Changing Flow Control setting on a port is not reflected in
Auto-negotiation's advertised capability.
Menu/Web-Browser Interface (PR_3534) — Display of mirror port configuration is
inconsistent between menu and WEB interface.