Software Fixes
Release G.07.20
CLI (PR_5242) — Information in the command “show boot-history” is not in the order
claimed (most recent first).
Crash (PR_4986) — The switch may crash with a message similar to: -> Bus error: HW
Addr=0x00ffffff IP=0x332c4530 Task='mSess1' Task ID=0x16a62f0 fp: 0x2e2e2e29
sp:0x016a61a0 lr:0x0010f028 This crash can occur when eight transceiver modules are
installed and the command “interface all” is typed in the configuration context.
Crash (PR_5236) — The switch may crash with a message similar to: -> AlphaSlaveAd-
drmgr.p 1021 this tim This crash can occur when a module is hot-swapped after downloading
new software to the switch without rebooting.
Crash (PR_5418) — The switch may crash with a message similar to: -> Software
exception at rtsock.c:459 -- in 'tNetTask', task ID = 0x1a225b0
Crash (PR_5635) — The switch may crash with a message similar to: -> Assertion failed:0,
file drvmem.c, line 167
Crash (PR_5679) — The switch may crash with a message similar to: -> Bus error: HW
Addr=0x00000000 IP=0x00000000 Task='mNSR' Task ID=0x1725148 fp: 0x0000c4b0
sp:0x012e9780 lr:0x00330674
Crash (PR_5846) — WhatsUpGold telnet scan can cause switch to run out of memory and
crash with error message similar to: -> malloc_else_fatal() ran out of memory
Date/Time (PR_5264) — The timezone can cause the date to wrap if the timezone is set to
a valid, but negative value (like -720) without previously configuring the switch's time. The
switch may report an invalid year (i.e. 2126).
Event Log (PR_5154) — When a module fails to download, the severity code is INFO
instead of WARNING.
FFI/Port Counters (PR_5280) — FFI and port counters don't have consistent values.
FFI/Port Counters (PR_5429) — No errors are reported by the FFI or port counters when
linking at 100 HDX on a Gigabit port with a duplex mismatch.
Flow Control (PR_5102) — Setting a port “X1” in 10-HDX, then attempting to turn on flow
control returns an error similar to: “Error setting value fl for port X2”. The error should read
“X1”.
GVRP (PR_5284) — Port does not register VLAN even though advertisements are received.
Hot-swap (PR_4900) — Hot-swapping a transceiver logs a message requesting to reboot
the switch in order to enable the port, while this is not necessary.
LACP/Port Security (PR_5059) — With LACP on, the command “port-sec a1 l c action
send-alarm” fails with a message similar to “learn-mode: Inconsistent value”.