8
9
RUN
NEXT
PROGRAM
ST
ART
TIMES
STATION RUN TIME
YEAR
MONTH
DA
Y
RUNNING
AM
PM
24 HR.
SUN MON
TUES WED
THUR
FRI SAT EVEN
/
ODD
SYSTEM OFF
RUN (BYPASS SENSOR)
SET DAYS TO WA
TER
MANUAL - SINGLE STATIO
N
MANUAL - ALL STATIONS
SET CURRENT DATE / TIME
SET WATERING START TIMES
SET STATION RUN TIMES
AC AC R RS C MV 1 2 3 4 5 6
9 V Batter
y
A
B
C
1
2
3
4
PROGRAM
ST
ART
TIMES
STAT ION RUN TIME
YEAR
MONTH
DA
Y
RUNNING
AM
PM
24 HR.
SUN MON
TUES WED
THUR
FRI SAT EVEN
/
ODD
E
C
Plus
Plus
PROGRAM
ST
ART
TIMES
STAT
A
B
C
1
2
3
4
PROGRAM
ST
ART
TIMES
STATION RUN TIME
YEAR
MONTH
DA
Y
RUNNING
AM
PM
24 HR.
SUN MON
TUES WED
THUR
FRI SAT EVEN
/
ODD
A B
D
PROGRAM
START
TIMES
RESET
SRC PLUS COMPONENTS
A – LCD Display
Start Time – Identifies selected start time (only one
start time per program is required).
Program Designator – Identifies program in use A,
B, or C.
Station Number – Identifies currently selected station
number.
LCD Display – Indicates various times and values.
Run Time – Duration of individual stations watering.
Year – Current calendar year.
Month – Current calendar month.
Day – Current calendar day.
Running – Indicates when watering is occurring.
AM/PM – Arrow differentiates either AM or PM time.
24 HR – 24-hour time is available in addition to AM
and PM.
Day of the Week – Identifies days of the week to water
or you can select to water on odd or even days.
(For all above LCD display items, when an arrow
cursor is flashing, that is what you are setting.)
B – Control Buttons
Button – Increases the selected flashing display.
Button – Decreases the selected flashing display.
Button – Advances the selected flashing display.
Button – Selects program A, B, or C.
C – Transformer
A 120 VAC Plug-in transformer (included in SRC -600i
and 900i models) supplies 24 VAC to the controller.
D – Control Dial
Run – Normal dial position for automatic and manual
operation.
Run (Bypass Sensor) – Used to disengage optional
weather sensor that may be wired to your system.
Set Current Date/Time – Allows current date and clock
time to be set.
Set Watering Start Times – Allows 1 to 4 start times
to be enabled in each program.
Set Station Run Times – Allows user to set each
station run time from 0 to 99 minutes.
Set Days To Water – Allows user to select individual
days to water or to select an odd or even watering
schedule, according to the date.
Manual – Single Station – Allows user to activate a
one time watering of a single station.
Manual – All Station – Allows user to activate a one
time watering of all stations or a few selected stations.
System Off – Allows user to discontinue all programs
and stop all watering until dial is returned to the RUN
position.
E – Wiring Compartment
Reset Button – This button will reset the controller.
All programmed data will remain intact.
9-Volt Battery – The alkaline battery will maintain the
current time if power to the transformer is discon-
nected. However, the battery will not operate any of the
watering activity (not included).
Transformer – The two wires from the plug-in
transformer are connected to the two AC terminals.
Terminal Strip Area – Use to attach transformer and
valve wires from their source to the controller.