EasyManuals Logo
Home>IBM>Network Hardware>AS/400

IBM AS/400 User Manual

IBM AS/400
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
Matching AS/400 parameters for a 5494 connected by X.21
You must coordinate communications configuration parameters between AS/400 and the 5494 remote
controller that is connected by X.21. These parameters are described in the following table. Then the
related fields and subfields from the 5494 configuration display are listed next. These values are followed
by the AS/400 configuration value and the matching 5494 value to be entered in the display subfield. You
can coordinate these values automatically or manually. Pick one of these ways:
v To automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller
(QAUTORMT) system value.
v To manually connect the AS/400 to a 5494 controller:
See Example: Connecting AS/400 to a 5494 controller connected by X.21 on page 53 for an
example of connecting AS/400 to a 5494 controller by X.21.
Use the following table to configure the AS/400 to a 5494 controller by X.21.
For more information about configuring the 5494, see these books:
v IBM 5494 Remote Control Unit Planning Guide, GA27-3936
v IBM 5494 Remote Control Unit Users Guide, GA27-3852,
AS/400
Prompt
AS/400
Parameter
5494
AS/400 Value 5494 Value NotesField Subfield
Connection
number
CNNNBR 15 - - -
Values specified for the AS/400
CRTCTLAPPC command and
for the 5494 Remote Control
Unit must match. If the AS/400
CRTCTLAPPC command
specifies CNNNBR(*DC), the
X.21 direct-call user facility
must be used to make the
connection.
Local
location
name
LCLLOCNAME H1 1 - - Values specified for the AS/400
CRTCTLRWS command and
for the 5494 Remote Control
Unit must match. This will
probably match LCLLOCNAME
in the network attributes. This
value will probably match the
LCLLOCNAME in the network
attributes.
Remote
control
point name
RMTCPNAME 13 - - - Values specified for the AS/400
CRTCTLAPPC command and
for the 5494 Remote Control
Unit must match.
Remote
network
identifier
RMTNETID 11 3 - - Values specified for the AS/400
CRTCTLAPPC and
CRTCTLRWS commands and
for the 5494 Remote Control
Unit must match. This will
probably match LCLNETID in
the network attributes and H1:2.
Remote
location
name
RMTLOCNAME 12 - - - Values specified for the AS/400
CRTCTLRWS command and
for the 5494 Remote Control
Unit must match.
52 Version 5

Table of Contents

Other manuals for IBM AS/400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM AS/400 and is the answer not in the manual?

IBM AS/400 Specifications

General IconGeneral
BrandIBM
ModelAS/400
CategoryNetwork Hardware
LanguageEnglish

Related product manuals