Matching AS/400 parameters for 3x74 controller
You must match the AS/400 configuration parameters with some configuration questions and sequence
numbers when you configure the 3174 and 3274 controllers.
For an example of connecting an AS/400 to a 3174 retail controller, see Example: Connecting an AS/400
to a 3174 control unit on page 61.
v Matching AS/400 parameters for a 3174 controller
v Matching AS/400 parameters for a 3274 controller on page 60
Matching AS/400 parameters for a 3174 controller
You must match the AS/400 configuration parameters with the configuration questions and sequence
numbers to configure the 3174 controller. These parameters are described in the following table.
For more information about configuring the 3174 controllers, see these books:
v 3174 Subsystem Control Unit Customizing Guide
v 3174 Establishment Controller Supplemental Customer Information for Configuration Support C Release
4 Ethernet Attachment, GA27-3994 has information about Ethernet support.
To configure the AS/400 to a 3174 controller:
v See Example: Connecting an AS/400 to a 3174 control unit on page 61 for an example of connecting
an AS/400 to a 3174 retail controller.
v Use the following table to connect an AS/400 to a 3174 remote controller.
AS/400
Prompt
AS/400
Parameter
3174
Configuration
Questions Notes
LAN remote
adapter
address
1
ADPTADR 084, 106 Ethernet Address
If the AS/400 system uses an Ethernet line to connect to the
3174 controller, use table C-3 on page C-4 in Appendix C:
Local Area Network Addressing Considerations of the
Communications Configuration
book to convert the
value specified for question 084. Specify the converted
address for the ADPTADR parameter on the CRTCTLRWS
or CRTCTLAPPC command.
Token-Ring Network Address of the 3174
If the AS/400 system uses a Token-Ring network line to
connect to the 3174 controller, values specified for question
106 and for the ADPTADR parameter on the CRTCTLRWS
or CRTCTLAPPC command must match.
If the AS/400 system uses an Ethernet line through an 8209
LAN Bridge, see Appendix C: Local Area Network
Addressing Considerations in the Communications
Configuration book.
58 Version 5

Table of Contents

Other manuals for IBM AS/400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM AS/400 and is the answer not in the manual?

IBM AS/400 Specifications

General IconGeneral
BrandIBM
ModelAS/400
CategoryNetwork Hardware
LanguageEnglish

Related product manuals