EasyManuals Logo
Home>IBM>Server>System x3200

IBM System x3200 User Manual

IBM System x3200
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
System-error log messages
A system-error log is generated by both the Remote Supervisor Adapter II SlimLine
and the mini-BMC. The system-error log can contain messages of three types:
Information Information messages do not require action; they record significant
system-level events, such as when the server is started.
Warning Warning messages do not require immediate action; they indicate
possible problems, such as when the recommended maximum
ambient temperature is exceeded.
Error Error messages might require action; they indicate system errors,
such as when a fan is not detected.
Each message contains date and time information, and it indicates the source of
the message (POST/BIOS or the service processor).
In the following example, the system-error log message indicates that the server
was turned on at the recorded time.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Date/Time: 2002/05/07 15:52:03
DMI Type:
Source: SERVPROC
Error Code: System Complex Powered Up
Error Code:
Error Data:
Error Data:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
The following table describes the possible system-error log messages and
suggested actions to correct the detected problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, System x3200 Types 4362 and 4363,” on page 67 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System-error log message Action
A system NMI was detected Make sure that the system software is operating correctly and does
not conflict with other software; the system software has created a
software NMI, or pressing the NMI button has created a service
NMI.
Alert accepted by remote system x; type:y, ID:z Information only.
Alert accepted from system x; type:y, sender’s
ID:z
Information only.
Alert ID x will be retried by sender; when
accepted by a remote system, it will have a
different ID
Information only.
Alert not accepted by remote system x; type:y,
ID:z
Information only.
Alert not accepted from system x; type:y,
sender’s ID:z
Information only.
54 System x3200 Types 4362 and 4363: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3200 and is the answer not in the manual?

IBM System x3200 Specifications

General IconGeneral
BrandIBM
ModelSystem x3200
CategoryServer
LanguageEnglish

Related product manuals