OPERATOR MANUAL
1) Place the machine in a well ventilated area.
2) Turn the machine off.

4) Connect the charger's AC power supply cord to a properly grounded receptacle.
5) The charger will automatically begin to charge and will automatically shut off once the
batteries are fully charged.
6) Upon completion of charging, disconnect the AC power supply cord.
PREVENTATIVE MAINTENANCE
WARNNING: Before performing any maintenance on the machine, be sure that
the power is turned off, or the batteries are disconnected!
WARNNING: Repairs are to be completed by authorized service centers only.
Any repairs completed by unauthorized persons will avoid the warranty.
DAILY MAINTENANCE
1) Remove pad driver / brush and clean with approved cleaner.
2) Drain recovery and solution tanks completely and rinse out with clean water. Visually check
the recovery tank for debris and clean out as necessary.
3) Raise squeegee assembly off floor and wipe it down with a damp towel. Be sure to store the
squeegee in the up position.


outside of machine to avoid damage to motor and wiring.
6) Unplug vacuum motor from power source and hose cuff & remove the drain hose from the
holder prior to removing the recovery tank when performing maintenance.
7) Check the condition of the squeegee blade wiping edge, rotate blade or replace it if worn.
ICE I18B/I18C

10
NOTE:
The charging status can be seen through the lights behind the transparent panel:
Yellow light on: Normal charging

Green light on: Fully charged, batteries ready for use.
Yellow lights ash: No batteries or incorrect wiring.
Red Yellow 2 Yellow 1
Green 2 Green 1
Battery Indicator Description: Green lights on: full power.
Yellow lights on, green lights off : medium power.
Red light on, other lights off: 20% power, the
maichine should be stopped and the batteries
should be recharged.
Red light flash: the batteries have already been
discharged deeply.
NOTE:
Frequently deep discharging will reduce
the life of the batteries, charge the
batteries when the red light is on.