MACHINE OPERATION
Do not operate machine unless you have read and understand this manual.

2) Turn brush motor switch(20) to “on” position.
3) Turn vacuum motor switch(21) to “on” position.
4) Rotate the ball valve(12) handle to vertical position. Solution will not begin to flow until the
operating triggers (9) are pulled.
5) To begin scrubbing, pull on the blue operating trigger(9), when this triggers is pulled, the pad

6) Begin scrubbing by moving the machine forward
Do not keep the machine in the same position with the pad / brush spinning,
or you might damage the floor.

WHILE OPERATING MACHINE
1) Occasionally open the cover tank(3) to see if there is any foam build-up. If excessive foam is
found, add defoamer to the recovery tank.
Foam must not enter the float shut-off screen, or damage can occur to the
vacuum motor. Foam will not activate the machine's float shut-off device.
2) Occasionally view the clear tube at the back left of the machine to check the amount of cleaning
solution that is left in the machine.

blades down with a damp cloth.
Do not use your fingers to wipe or remove debris from the blades, as injury
may occur.
When the solution tank runs empty, turn off the brush switch and ball valve of solution tank. Keep
the squeegee down and continue to vacuum until all the dirty water is picked up.
TANK DRAINING
1) Turn the switches on the control panel to “off ” position.
2) Raise the squeegee, transport machine to approved area for draining tank(s).
Any time scrubbing is completed, or when refilling solution tank, the
recovery tank should be drained and cleaned.
If the recovery tank is not drained when the solution tank has been refilled,
foam or water may enter the float shut-off mechanism and cause damage to
the vacuum motor.