*This output level of a standard signal generator (SSG) is indicated as SSGs open circuit.
4 - 4
4-3 RECEIVER ADJUSTMENTS
RX PEAK
MIXER
BALANCE
FM
DISTORTION
ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT LOCATION UNIT ADJUST
1
2
3
1
2
1
2
Display frequency: 14.100000 MHz
Mode : USB
Filter : 2.4 kHz
[P.AMP] : P.AMP1
[ATT] : OFF
Connect an SSG to [ANT1] con-
nector and set as :
Frequency : 14.101500 MHz
Level : 10 µV* (87 dBm)
Modulation: 1 kHz/±7.5 kHz dev.
Receiving
[DUAL WATCH] : ON
Sub display freq. : 14.100000 MHz
Mode : USB
[BAL] : Max. CW
Set an SSG as :
Level : 10 µV* (87 dBm)
Receiving
Display frequency: 14.100000 MHz
Mode : USB
[DUAL WATCH] : OFF
Set following selections, controls
and functions as :
Filter : 2.4 kHz, [ATT] : OFF
[AGC]: MID , [BAL] : Center
PBT1 : Center , PBT2 : Center
[NB] : OFF , [RIT] : OFF
[P.AMP] : P.AMP1
[RF/SQL] : Center
[
AUTO NOTCH
]: OFF
[
NOTCH
] : Center
[NR] switch : OFF
[NR] level : Max. CCW
[MONITOR] : OFF
Connect an SSG to [ANT1] con-
nector and set as :
Frequency : 14.101500 MHz
Level : 1 µV* (107 dBm)
Modulation: OFF
Receiving
Display frequency: 0.030000 MHz
Sub display freq. : 0.030000 MHz
Mode : USB
[BAL] : Max. CCW
Apply no no RF signal to [ANT1]
connector.
Receiving
[BAL] : Max. CW
Receiving
Display frequency: 14.100000 MHz
Sub display freq. : 14.100000 MHz
Mode : FM
[BAL] : Max. CCW
Connect an SSG to [ANT1] con-
nector and set as :
Frequency : 14.100000 MHz
Level : 500 µV* (53 dBm)
Modulation:
1 kHz/±7.5 kHz Dev.
Receiving
[BAL] : Max. CW
Receiving
Rear
panel
Rear
panel
Rear
panel
Connect an AC milli-
volt meter to [EXT
SP] connector with
an 8 load.
Connect an AC milli-
volt meter to [EXT
SP] connector with
an 8 load.
Connect an distortion
meter to [EXT SP]
connector with an
8 load.
Maximum audio output
level
Minimum noise output
level
Minimum distortion
level
RF
MAIN
RF
RF
L513,
L721,
L722,
L943
L613
L111,
L112,
L113
R516
R616
C555
C655

Other manuals for Icom IC-756PRO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-756PRO and is the answer not in the manual?

Icom IC-756PRO Specifications

General IconGeneral
BrandIcom
ModelIC-756PRO
CategoryTransceiver
LanguageEnglish

Related product manuals